Utility · TX0990002

CITY OF QUANAH

CITY OF QUANAH (PWSID TX0990002) is an active community water system in Texas serving about 2,662 people through roughly 1,256 service connections. Its primary source is listed as purchased surface water. Cities/areas associated with this system in EPA geographic data: Quanah. In recent EPA records indexed here, we found 37 violation record(s), including 4 health-based and 3 still listed as addressed/unaddressed (not fully resolved). This page summarizes public EPA SDWA/ECHO data for educational purposes. It is not a substitute for your utility’s official Consumer Confidence Report or public notices.

2,662population served
1,256service connections
4health-based viol.
37viol. rows indexed

System facts

  • PWSID: TX0990002
  • Type: Community water system (active)
  • Primary source: Purchased surface water
  • Owner type: Local government
  • Wholesaler flag: No
  • Phone (EPA record): 940-663-5336
  • Address (EPA record): PO BOX 629, Quanah 79252

Service geography

Cities/areas:

Quanah

Counties: Hardeman

ZIPs served (EPA geo): —

Recent violation records (indexed subset)

Showing up to 40 recent violation identities (2021+ when dated), deduplicated from SDWA_VIOLATIONS_ENFORCEMENT. Status meanings come from EPA’s data dictionary (Resolved / Addressed / Unaddressed / Archived).

BeginContaminant / issueViolationCategoryHealth-basedStatusResult / MCL
12/30/2022Lead and Copper RuleLead Consumer NoticeMRNoResolved— / MCL TT
12/19/2021Public NoticePublic Notification Violation for NPDWR ViolationOtherNoResolved— / MCL
12/09/2023Public NoticePublic Notification Violation for NPDWR ViolationOtherNoResolved— / MCL
10/01/2025ChlorineMonitoring and Reporting (DBP)MRNoResolved— / MCL 4.0 mg/L
10/01/2025Lead and Copper RuleFollow-up Or Routine LCR Tap M/RMRNoUnaddressed— / MCL TT
10/01/2025TTHMMaximum Contaminant Level Violation, AverageMCLYesArchived.096 MG/L / MCL 0.080 mg/L
10/01/2024ChlorineMonitoring and Reporting (DBP)MRNoResolved— / MCL 4.0 mg/L
10/01/2023ChlorineMonitoring and Reporting (DBP)MRNoResolved— / MCL 4.0 mg/L
10/01/2021Public NoticePublic Notification Violation for NPDWR ViolationOtherNoResolved— / MCL
09/03/2023Public NoticePublic Notification Violation for NPDWR ViolationOtherNoResolved— / MCL
09/01/2023Public NoticePublic Notification Violation for NPDWR ViolationOtherNoResolved— / MCL
08/01/2024Revised Total Coliform RuleMonitoring, Routine (RTCR)MONNoResolved—
08/01/2022Revised Total Coliform RuleMonitoring, Routine (RTCR)MONNoResolved—
08/01/2021Public NoticePublic Notification Violation for NPDWR ViolationOtherNoResolved— / MCL
07/02/2025LEAD AND COPPER RULE REVISIONSNotification, Known or Potential LSLRPTNoResolved—
07/01/2025TTHMMaximum Contaminant Level Violation, AverageMCLYesArchived.128 MG/L / MCL 0.080 mg/L
07/01/2023ChlorineMonitoring and Reporting (DBP)MRNoResolved— / MCL 4.0 mg/L
07/01/2022ChlorineMonitoring and Reporting (DBP)MRNoArchived— / MCL 4.0 mg/L
07/01/2021ChlorineMonitoring and Reporting (DBP)MRNoResolved— / MCL 4.0 mg/L
06/26/2026Public NoticePublic Notification Violation for NPDWR ViolationOtherNoUnaddressed— / MCL
06/18/2023Public NoticePublic Notification Violation for NPDWR ViolationOtherNoResolved— / MCL
06/01/2022Revised Total Coliform RuleMonitoring, Routine (RTCR)MONNoResolved—
05/14/2026Public NoticePublic Notification Violation for NPDWR ViolationOtherNoUnaddressed— / MCL
05/01/2021Revised Total Coliform RuleMonitoring, Routine (RTCR)MONNoResolved—
04/04/2025TTHMFailure Submit IDSE/Subpart V Plan RptMRNoResolved— / MCL 0.080 mg/L
04/01/2026TTHMMaximum Contaminant Level Violation, AverageMCLYesArchived.132 MG/L / MCL 0.080 mg/L
04/01/2024ChlorineMonitoring and Reporting (DBP)MRNoResolved— / MCL 4.0 mg/L
04/01/2022ChlorineMonitoring and Reporting (DBP)MRNoArchived— / MCL 4.0 mg/L
04/01/2021ChlorineMonitoring and Reporting (DBP)MRNoResolved— / MCL 4.0 mg/L
01/16/2025Public NoticePublic Notification Violation without NPDWR ViolationOtherNoResolved— / MCL
01/16/2025Public NoticePublic Notification Violation without NPDWR ViolationOtherNoResolved— / MCL
01/01/2026Revised Total Coliform RuleMonitoring, Routine (RTCR)MONNoResolved—
01/01/2026TTHMMaximum Contaminant Level Violation, AverageMCLYesArchived.108 MG/L / MCL 0.080 mg/L
01/01/2025ChlorineMonitoring and Reporting (DBP)MRNoResolved— / MCL 4.0 mg/L
01/01/2022Public NoticePublic Notification Violation for NPDWR ViolationOtherNoResolved— / MCL
01/01/2022ChlorineMonitoring and Reporting (DBP)MRNoArchived— / MCL 4.0 mg/L
—Unspecified—No——

Lead & copper rule sample highlights

Codes PB90 / CU90 in SDWIS typically represent 90th percentile lead/copper monitoring results under the Lead and Copper Rule.

Lead (PB90)

  • 12/31/2023: 0 mg/L
  • 12/31/2002: .0015 mg/L
  • 12/31/1999: .0009 mg/L
  • 12/31/1998: .0024 mg/L
  • 12/31/1997: .0013 mg/L
  • 12/31/1994: .0064 mg/L
  • 12/31/1993: .0064 mg/L
  • 06/30/1997: .0021 mg/L

Lead explainer →

Copper (CU90)

  • 12/31/1993: 1.48 mg/L

Copper explainer →

FAQs

What does PWSID TX0990002 mean?

A Public Water System Identification number uniquely identifies a system in EPA’s Safe Drinking Water Information System (SDWIS). Texas IDs start with TX.

How current is this page?

Systems and geography reflect the EPA SDWA quarterly snapshot used for this build. Violation rows are a filtered recent subset (generally 2021+) and capped for readability—always confirm on ECHO and your CCR.

What should I do if I see a health-based violation?

Read the dates and status. Contact the utility for context, check for public notices, and review the newest Consumer Confidence Report. For medical concerns, talk with a clinician—this site is educational only.

Do lead/copper samples mean my home is safe?

LCR samples are utility monitoring results (often 90th percentile summary codes like PB90/CU90), not a test of every tap. Home plumbing can differ. Consider a certified lab test if you have reason for concern.